Philips Respironics · Under the nose full face mask (hybrid, minimal contact)

Philips Respironics Amara View

A minimal contact full face mask whose cushion sits under the tip of your nose and around your mouth, so it does not touch your nasal bridge. Unlike DreamWear Full Face, the hose connects in front with a quick release elbow. One modular frame takes every cushion size. Philips notes that one configuration of this mask contains magnets.

This mask uses magnets

Philips states that Amara View "has a configuration that contains magnets that may interfere with certain implants or medical devices" (the magnetic headgear clip version). Philips Respironics issued an Urgent Medical Device Correction dated August 29, 2022 for this mask, and the FDA published a safety communication about it on September 6, 2022 ("Certain Philips Respironics Masks for BiPAP, CPAP Machines Recalled Due to Safety Issue with Magnets That May Affect Certain Medical Devices"). The updated Philips contraindication reads: "Use of the mask is contraindicated for patients and their household members, caregivers, and bed partners that may be in close vicinity to patients using the masks, that have implanted devices that may be affected by magnets, including but not limited to": pacemakers; implantable cardioverter defibrillators (ICD); neurostimulators; magnetic metallic implants, electrodes or valves placed in the upper limbs, torso, or higher (neck and head); CSF (cerebral spinal fluid) shunts such as a VP shunt; aneurysm clips; embolic coils; intracranial aneurysm intravascular flow disruption devices; metallic cranial plates, screws, burr hole covers and bone substitute devices; metallic splinters in the eye; ocular implants (such as glaucoma or retinal implants); certain contact lenses with metal; implants to restore hearing or balance that have an implanted magnet (such as cochlear implants, implanted bone conduction hearing devices and auditory brainstem implants); magnetic denture attachments; metallic gastrointestinal clips; metallic stents (aneurysm, coronary, tracheobronchial, biliary); implantable ports and pumps (such as insulin pumps); hypoglossal nerve stimulators; devices labeled as MR (magnetic resonance) unsafe; and magnetic metallic implants not labeled for MR or not evaluated for safety in a magnetic field. The updated Philips warning reads: "Magnets with a magnetic field strength of 400 mT are used in the mask. With the exception of the devices identified in the contraindication, ensure the mask is kept at least 6 inches (approx. 15.24 cm) away from any other medical implants or medical devices that can be impacted by the magnetic fields." Philips reported 14 cases of possible interference with implanted devices, including pacemaker failure and defibrillator resets. If any of this applies to you or to anyone who sleeps near you, stop using the mask, call your doctor about a non-magnetic mask, and contact Philips Customer Care at 1-800-345-6443.

SizesCushion: Small, Medium, Large, One modular frame for all cushion sizes, Headgear: standard and large
Works withAll standard 22 mm CPAP, APAP and BiPAP machines from any brand (ResMed, Philips, Fisher & Paykel, React Health and others). Select the matching mask type in your machine's comfort menu if it has one.

Usually suits

  • Mouth breathers who want a smaller full face mask
  • People with bridge soreness from over the nose full face masks
  • Back sleepers or people who prefer a front hose

Design

  • Under the nose full face cushion with no nasal bridge contact
  • Tube in front design with a quick release elbow
  • One modular frame for all cushion sizes
  • Open field of view for glasses, reading and TV
  • Some configurations use magnetic headgear clips

Strengths and trade-offs

  • Covers nose and mouth without touching the nasal bridge
  • Quick release elbow lets you disconnect the hose at night without taking the mask off
  • Simple, small parts list with a single frame
  • The magnetic clip configuration is contraindicated for some implants, in you or a bed partner
  • Front hose can tug when you turn over, unlike top of head designs
  • Only three cushion sizes

Finding your size

Philips' Amara View sizing guide has a printable fitting gauge (print at 100 percent and check it against a credit card). Place the gauge on your nose and choose the size by which area your nose reaches: Small, Medium or Large. Amara View sizes differently from DreamWear Full Face, so do not assume your DreamWear size carries over. Philips recommends having a clinician or sleep therapist confirm the fit.

How to fit it

  1. Find your size

    Use the Amara View gauge on your nose and pick Small, Medium or Large by which area your nose reaches.

  2. Put the mask on

    Hold the cushion under your nose and over your mouth, and pull the headgear over your head. Attach the lower headgear clips to the frame.

  3. Adjust evenly

    Adjust the top straps, then the bottom straps, a little at a time and evenly on both sides. The cushion should seal under your nose without pressing up into the nostrils.

  4. Connect and test

    Connect the hose to the elbow, start the machine and lie down in your usual position. Make small adjustments to stop leaks rather than tightening hard.

Common problems and fixes

Leak into the eyes or at the nose

Check that the cushion is under the nose and not pushed up onto it. Loosen the top straps slightly and recheck your size with the gauge.

Leak at the chin or mouth corners

Tighten the bottom straps evenly. If you open your mouth wide while asleep, a chinstrap can help keep the seal.

Hose pulling the mask when you turn over

Use a hose hanger or hose management system to take the hose weight off the mask.

Red marks on cheeks

Straps are usually too tight. Loosen them, and consider mask liners or strap covers.

Cleaning and care

Hand wash the cushion and frame daily in warm water with a mild liquid dish soap, rinse thoroughly and air dry. Wash the headgear by hand with mild soap and hang it to dry. Inspect the cushion for tears or stiffness. Do not use bleach, alcohol, or ozone or UV cleaners, and follow the Instructions for Use for your exact version.

How often to replace parts

Mask
1 every 3 months (Medicare A7030, full face mask)
Cushion
Up to 1 per month (Medicare A7031, full face cushion)
Headgear
1 every 6 months (Medicare A7035)

Get a free reminder when each part is due →

Supplies that can help

CPAP chinstrap

A soft strap that supports the jaw to help keep the mouth closed, used mainly with nasal and nasal pillow masks to reduce mouth leaks.

CPAP mask liners

Soft fabric liners that sit between your skin and the mask cushion to reduce skin irritation, red marks and the noisy leaks some people get from …

CPAP hose management system

A stand or arm that lifts the tubing above the bed so it does not drag on the mask when you turn over.

CPAP hose hanger

A simple hook or hanger for drying CPAP tubing vertically after washing, and for keeping it off the floor.

Mild unscented soap for CPAP cleaning

Plain, mild dish soap is the cleaning agent most CPAP makers and the FDA point to for masks, tubing and humidifier chambers.

Retailer links are affiliate links. We may earn a commission at no cost to you.

Frequently asked questions

Does the Amara View have magnets?

Philips says the mask has a configuration with magnets, and Amara View was included in the 2022 magnet correction and FDA safety communication. Check whether your headgear clips are magnetic; if you or a bed partner has a listed implant, do not use the magnetic version.

What is the difference between Amara View and DreamWear Full Face?

Both seal under the nose and around the mouth. Amara View has the hose in front with a quick release elbow; DreamWear Full Face routes air through the frame to the top of your head. They size differently, so use each mask's own gauge.

Will Amara View work if I have a beard?

Because it seals around the mouth, a thick mustache or beard can break the seal at the lip and chin. Trimming the area where the cushion sits often helps.

Sources

Last reviewed October 11, 2026. How we research · Report an error